U-Values – Wall Examples

To act as a radiant barrier the HRM must be installed facing at least one air space, usually 19 to 25mm. 23mm is preferred as this allows electrical and piped services to be installed in front of the membrane. Most of the heat conducting through the structure and crossing the air space as infrared energy is blocked.  The air within the air space will eventually warm and rise (Convection). However, the warmed air cannot escape as all joins between adjacent HRM sheets and structural components are sealed using the company’s heat reflecting (HR) self-adhesive tape.

 

Please see a selection of sample U-Value Calculations for walls below.  To see further examples please click here to download our Enhanced U-Value Document.

 


 Wall U-Value Examples

 

Standard Timber Frame House

 

Without Thermo-Foil® ES                                               With Thermo-Foil® ES

U – Value – 0.30                                                            U-Value – 0.249

 

Timber Frame Warm Frame or Hybrid

 

Without Thermo-Foil® ES                                               With Thermo-Foil® ES

U – Value – 0.297                                                          U-Value – 0.248

 

Masonry Unfilled Cavity Wall

 

Without Thermo-Foil® ES                                               With Thermo-Foil® ES

U – Value – 1.55                                                            U-Value – 0.759

 

Masonry Solid Wall

 

Without Thermo-Foil® ES                                               With Thermo-Foil® ES

U – Value – 2.08                                                            U – Value – 0.871

 

Light Steel Warm Frame

 

Without Thermo-Foil® ES                                               With Thermo-Foil® ES

U – Value – 0.351                                                          U – Value – 0.284

 

Internal Partition Wall

 

Without Thermo-Foil® ES                                               With Thermo-Foil®ES

U – Value – 1.742                                                          U – Value – 0.802 (1 layer) 0.521 (2 layers)