For more than 15 years we have been manufacturing our range, constantly testing and improving our products. We have BBA certification, undergoing regular audits, and hold fire certificates to both BS 476 part 6 and 7.
Other certification include;
Dubai Municipality Approval
Masdar Approval
Singapore Green Council Approval
When it comes to quality every product in the Apollo range is manufactured in the UK under an ISO 9001 Certified Quality Management System.
Apollo's HRM is the essential barrier to the elements for any building
It has been tested that for every 120m2 (1 roll) of our HRMs installed over 1400kg of carbon dioxide emissions are saved per annum.
Thermo-Foil®ES and Eco-Brite® are some of the most beneficial product ranges in improving energy efficiency and reducing greenhouse gas emissions no matter where they are installed.
Whether in roofs, walls, under floors, HVAC ducts correctly installed Apollo’s HRMs have been tested and proven to enhance u-values and provide significant lifelong thermal insulation benefits.
Our patented technology ensures that 96.1% of infrared energy striking the bright, tarnish resistant surfaces is blocked. As a result buildings are kept cooler in hot climates and warmer in cold climates. Correctly installed the systems offered will control heat convection, eliminate air leakage and infiltration.
They are simple to install, and are easily moulded around door or window frames and will not spring back. The products function as excellent vapour barriers, keeping other insulation dry thus maintaining its performance. Acting as air barriers, preventing air leakage and infiltration through the building’s envelope, ensures help to reduce energy bills.
To act as a radiant barrier the HRM must be installed facing at least one air space, usually 19 to 25mm. This also creates a service void for electrical and piped services to be installed in front of the membrane.
Please see below for a selection of examples of the improvement that installing Apollo’s membranes can achieve.
We are more than happy to do a personalised U-value calculation for your structure free of charge.
TIMBER FRAME WALL
140mm Mineral Wool λ = 0.038 W/mK
U-Value WITHOUTApollo Foil
0.29W/m2K
U-Value WITH Apollo Foil
0.24W/m2K
90mm Board insulation λ = 0.023 W/mK
U-Value WITHOUT Apollo Foil
0.32W/m2K
U-Value WITH Apollo Foil
0.25W/m2K
ATTIC ROOM
150mm Borad Insulation λ = 0.023 W/mK
U-Value WITHOUTApollo Foil
0.19W/m2K
U-Value WITH Apollo Foil
0.17/Wm2K
MASONRY WALL
120mm Mineral Batt λ = 0.038 W/mK
U-Value WITHOUTApollo Foil
0.29W/m2K
U-Value WITH Apollo Foil
0.24W/m2K
CEILING
200mm Mineral Wool λ = 0.042 W/mK
U-Value WITHOUTApollo Foil
0.19W/m2K
U-Value WITH Apollo Foil
0.17W/m2K
SUSPENDED TIMBER FLOOR
75mm Board Insulation λ = 0.023 W/mK
U-Value WITHOUTApollo Foil
0.28W/m2K
U-Value WITH Apollo Foil
0.24W/m2K
LIGHT STEEL FRAME
2 Layers of Eco-Brite
0.24W/m2K